Flame retardant sheathed control cable
- cpfl:
Description
1. Purpose: this product is used for wiring electrical appliances and instruments in power distribution devices with rated ac voltage of 500V or dc voltage of 1000V and below.
2. Product characteristics: the long-term allowable operating temperature of the cable conductor shall not exceed 70℃. When laying, the temperature of the cable shall not be less than 0℃, and the bending radius shall not be less than 10 times of the outside diameter of the cable. The cable with armor or copper tape shielding structure shall not be less than 12 times the outer diameter of the cable.
3. Product standard: gb9330.2-88 PVC insulated and sheathed control cable
4. Cable type, name and scope of use
model | The name says | Using range |
ZR - KVV | Flame retardant PVC insulated, flame retardant PVC sheathed control cable | Lay indoors, in cable ditches, in pipes and underground. |
ZR - KVVP | Flame retardant PVC insulated, flame retardant PVC sheathed copper wire braid shield control cable | Laid indoors, in cable ditches, in pipes and underground, with anti-interference capability |
ZR - KVVP | Flame retardant PVC insulated, flame retardant PVC sheathed soft control cable | Laying in the indoor movement requires soft and other occasions. |
ZR - KVVRP | Flame retardant PVC insulated, flame retardant PVC sheathed copper wire braid shielded soft control cable | As above has anti - interference ability. |
ZR - KVVP2 | Flame retardant PVC insulated, flame retardant PVC sheathed copper tape wrapped shielding control cable | Same as above. |
ZR - KVV22 | Flame retardant PVC insulation, flame retardant PVC sheathed steel tape armored control wire | Laid indoors, in cable ditches, in pipes and underground, able to withstand large external mechanical forces. |
ZR - KVV32 | Flame retardant PVC insulated, fine wire armored flame retardant PVC sheathed control cable | Laid indoors, in cable ditches, pipes, shafts and underground, able to withstand a certain tension. |
Note: flame retardant (ZR) and halogen-free flame retardant (ZRA) control cables can be manufactured according to user requirements.
5. Production scope
model | The rated voltage (V) | Conductor nominal cross section (mm2) | |||||||
0.5 | 0.75 | 1.0 | 1.5 | 2.5 | 4 | 6 | 10 | ||
some | |||||||||
ZR - KVV ZR - KVVP | 450/750 | - | 2-61. | 2-14 | 2-10 | ||||
ZR - KVVP2 | - | 4-61. | 4-14 | 4-10 | |||||
ZR - KVV22 | - | 7-61. | 4-61. | 4-14 | 4-10 | ||||
ZR - KVV32 | - | 19-61. | 7-61. | 4-14 | 4-10 | ||||
ZR - KVVR | 4-46 | - | - | ||||||
ZR - KVVRP | 4-61. | 4-48 | 4-4 | - |