Hello! Main Products: Anticorrosive Materials, Heat Preservation Materials, Waterproof Materials, etc

Pressure instrument series

hotsearch
15613415268279.jpg
  • 15613415268279.jpg

Digital display electric contact pressure gauge

cpfl:
The 100/150 series of digital and electric contact pressure gauges use a pressure sensor with good s…
Description

The 100/150 series of digital and electric contact pressure gauges use a pressure sensor with good stability as its sensing element to detect the process medium pressure. Stainless steel interface is compatible with various media. Digital and electric contact pressure gauges are mainly used in petrochemical, coal mine hydraulic, power station dam, automotive electronics, liquid level measurement. It has waterproof and explosion-proof fully closed structure. The instrument is equipped with lower limit setting device for automatic control or communication of the operating system. The anti-vibration structure of the digital display electric contact pressure gauge can suppress the dither and impact of the pointer, protect the contact, so that the instrument indication is clear, the signal switch is reliable, the work is stable.

Model name:

 

Technical parameters:

 

Measuring range MPa

- 0.1-0.15; - 0.1-0.3; - 0.1-0.5; - 0.1-0.9; - 0.1-1.5; - 0.1-2.4 0-0.25; 0-0.4; 0-0.6; 0-1.0; 0-1.6; 0-2.5; 0-4.0; 0-6.0; 0 to 10; 0 to 16; 0 to 25; 0 to 40; 0-60

The accuracy of %

+ / - 0.5

Contact electrical parameters

Working voltage

24 VDC 380 vac

Working current

5 a

Power (non-inductive load)

5 a / 240 vac

The connector

X14K4P

 

Operating temperature: -25℃~55℃ working pressure upper limit: 2/3 working environment vibration frequency shall not be greater than the upper limit of the meter shall not be greater than 25Hz, amplitude shall not be greater than 0.5mm

External dimensions:

 

model

External dimension mm

a.

B

C

D

d

d0

M

- 100.

44

45

18

100

/

/

20 x1. 5

- 100 - t

44

46

19

118

5.5

- 100 - z

43

45

34

/

/

- 100 zq

43

45

44

118

5.5

- 150.

50

47

19

149

/

/

20 x1. 5

- 150 - t

50

48

20

165

5.5

- 150 - z

51

47

55

/

/

- 150 zq

51

47

55

165

5.5

Note: connection threads are available on request

Wiring diagram:

Instructions for use and ordering: the working environment of the instrument should be free of corrosive gas. Please specify the name, model and measurement range of the order.


Browse:
Return To The Top

分享到: