End face thermal resistance
- cpfl:
Description
WZCM and WZPM series end thermal resistance elements are wound by specially treated wire with the towel at the front of the thermometer. Compared with the general axial thermal resistance, the end thermal resistance can reflect the actual temperature of the end face more accurately and quickly, and is suitable for measuring the end face temperature of the bearing shell or other parts.
● main technical parameters
The name of the | The temperature range is ℃ | Allowable deviation delta t℃ | Degree, |
End copper resistance | - 50-100 | Plus or minus (0.3 + 6.0 x 10-3 | t |) | Or Cu100 Cu50 (G) |
End face platinum resistance | - 150-200 | B: - (0.30 + 0.005 | t |) | Pt100 |
Measurement range and tolerance (unit: mm) name temperature measurement range allowable deviation of temperature delta t ° c dividing sign end face copper resistance -50-100 ±(0.3+6.0×10-3|t|) Cu50 (G) or Cu100 end face platinum resistance -150-200 class B: ±(0.30+0.005|t|) Pt100 ●
Type no. | Degree, | Structural features | The temperature range is ℃ | Protective tube material | Thermal response time | specifications | Nominal pressure | Outer lead length L (mm) | |
Diameter d (mm) | M (mm) | ||||||||
WZCM - 201. | Cu50 Cu100 | Fixed embedded or threaded connection | - 50-100 | Copper T2 - Y | The < 15 | Φ 6 | M8x0 .75 | Atmospheric pressure | 500, 1000, 1500, 2000, 2500 |
WZPM - 201. | Pt100 | - 150-200 | The < 15 | Φ 8.7 | M10x1 | ||||
WZPM - 201 - b |
Note: wzpm-201b adopts the imported component wzpm-018, the accuracy class is A.