Integrated orifice flowmeter
- cpfl:
Description
Overview SZLG series integration orifice meter is the standard orifice differential pressure transmitter with multiple parameters or differential pressure transmitter, temperature transmitter and pressure transmitter of high contrast range pressure flow device, orifice flow meter can measure the rate of flow of gas, steam, liquid, widely used in petroleum, chemical industry, metallurgy, electricity, heating, water supply in areas such as process control and measurement. Nominal diameter :15 mm ≤DN≤1200mm 2. Nominal pressure: PN≤10MPa 3. Operating temperature: -50℃≤t≤550℃ 4
model | Said Ming | |||||||||
SZLG | Throttling device (integrated orifice flowmeter) | |||||||||
Code name | According to its structure characteristic two big basic classification | |||||||||
K. | Orifice plate | |||||||||
P | Nozzle etc. | |||||||||
Code name | Nominal pressure (105Pa) | |||||||||
2.5 | 2.5 | |||||||||
10 | 10 | |||||||||
16 | 16 | |||||||||
25 | 25 | |||||||||
64 | 64 | |||||||||
100 | 100 | |||||||||
200 | 200 | |||||||||
Code name | Diameter (mm) | |||||||||
15~1200 | 15 to 1200 mm | |||||||||
Code name | Subdivide by its structural form | |||||||||
H. | Standard orifice (ring chamber) | |||||||||
Y | Standard orifice (flange) | |||||||||
K. | Standard orifice plate (drill hole) | |||||||||
i. | ISA 1932 nozzle | |||||||||
L | The length to diameter nozzle | |||||||||
W. | Venturi nozzle | |||||||||
G | Classical venturi tube | |||||||||
s. | Double orifice | |||||||||
Q | Segmental orifice | |||||||||
Z | Tapered inlet orifice plate | |||||||||
R | A quarter circle orifice | |||||||||
P | The eccentric orifice plate | |||||||||
N | Integral orifice plate | |||||||||
X | Wedge orifice | |||||||||
T | Special throttling devices not included above | |||||||||
Code name | medium | |||||||||
1 | liquid | |||||||||
2 | gas | |||||||||
3 | steam | |||||||||
4 | High temperature liquid | |||||||||
Code name | Compensation in the form of | |||||||||
N | No pressure, temperature compensation | |||||||||
P | Output with pressure compensation | |||||||||
T | With temperature compensation output | |||||||||
Q | Output with pressure and temperature compensation | |||||||||
Code name | Transmitter differential pressure range | |||||||||
0 | Differential pressure range | |||||||||
1 | Low differential pressure range | |||||||||
2 | Medium differential pressure range | |||||||||
3 | Height differential pressure range | |||||||||
Code name | Live display or not | |||||||||
W. | Throttle device sensor | |||||||||
X | Intelligent throttling device (flowmeter) |