Electromagnetic flowmeter

cpfl:
Overview: the measuring principle of LD series electromagnetic flowmeter is Faraday's law of el…
Description

Overview: the measuring principle of LD series electromagnetic flowmeter is Faraday's law of electromagnetic induction. The main components of the sensor are: measuring tube, electrode, excitation coil, iron core and yoke housing. Electromagnetic flowmeters are mainly used to measure the volume flow of conductive liquids and grout in closed pipes. Including acid, alkali, salt and other corrosive liquid. Electromagnetic flowmeter is widely used in petroleum, chemical, metallurgy, textile, food, pharmaceutical, paper and other industries as well as environmental protection, municipal management, water conservancy construction and other fields. 1. The measurement is not affected by changes in fluid density, viscosity, temperature, pressure and conductivity; 2. No obstructing flow parts in the measuring tube, no pressure loss, low requirements for straight pipe section; 3. Series nominal sizes DN15 ~ DN3000. Sensor lining and electrode materials are available in a variety of options; 4. The converter adopts novel excitation method, low power consumption, zero point stability and high accuracy. Flow range up to 1500:1; 5. The converter can be integrated or separated from the sensor; 6. The converter adopts 16-bit high-performance microprocessor, 2x16LCD display, convenient parameter setting and reliable programming; 7. The electromagnetic flowmeter is a two-way measuring system with three integrators: forward total, reverse total and difference total; It can display. Zhuang, reverse flow, and with a variety of output: current, pulse, digital communication, HART; 8. The converter adopts surface mounting technology (T) with self-test and self-diagnosis functions; Main technical data: machine and sensor technical data

 

Execution standard

/ T 9248-1999

Nominal diameter

15, 20, 25, 32, 40, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 2200, 2400, 2600, 2800, 3000

High velocity

15 m/s

The accuracy of

DNl5 to 24 ")

± 0.3% (flow rate ≥1m/s); ±3mm/s(flow rate <1m/s)

DN700 - DN3000

± 0.5% of the indicated value (flow rate ≥0.8m/S); ±4mm/s(flow rate <0.8m/s)

Fluid conductivity

P 5 us/cm

Nominal pressure

4.0 MPa

1.6 MPa

1.0 MPa

0.6 MPa

6.3, 10 mpa

DNl5 ~ 6

DNl5 to 24 ")

DN200 ~ DN1000

DN700 ~ DN3000

Special orders

The environment temperature

The sensor

- 25 ℃ - 10 to 60 ℃

Converter and one body

- 10 ℃ - 10 to 60 ℃

The lining material

Polytetrethylene, polybutadiene rubber, polyurethane, polyvinyl propylene (F46), mesh PFA

High fluid temperature

- size

70 ℃

The separation type

Polybutadiene rubber lining

80 ℃; 120℃(indicated when ordering)

Polyurethane lining

80 ℃

Polytetrethylene lining

100 ℃; 150℃(indicated when ordering)

Polyvinyl propylene (F46)

And network PFA

Signal electrode and grounding electrode materials

Stainless steel 0Crl8Nil2M02Ti, haselloy C, haselloy B, titanium, tantalum, platinum/iridium alloy, stainless steel coated with tungsten carbide

Electrode scraper mechanism

12 - DN3000

Joint flange material

Carbon steel

Earth flange material

Stainless steel 1 crl8ni9ti

Import paolan materials

DN65 - DNl50

Stainless steel 1 crl8ni9ti

DN200 ~ DNl600

Carbon steel ten stainless steel 1Crl8Ni9Ti

Enclosure protection

DNl5 ~ DN3000 separate rubber or polyurethane lined sensor

IP65 or IP68

Sensors, - type flow meters and separation type converters

IP65

Spacing (separate type)

The converter is generally no more than 100m from the sensor

Converter technical data

 

The power supply

communication

85-265 - v, 45-400 hz

dc

11-40 v

Operation keys and display

touch-tone

4 thin film buttons can be set to select all parameters, or can be used to set the converter programming PC (RS232); Line 3 LCD wide viewing Angle, wide temperature, with backlight display; Row display flow value; Line 2 shows the unit of flow; The third line shows the flow percentage, forward total, reverse total, difference total, and flow rate.

The magnetic key type

Two magnetic keys are used to select and reset the display parameters, and the converter is programmed by PC (RS232). Line: magnetic key selection: display flow percentage, forward total, reverse total, difference total, and flow rate. Line 2: display traffic.

Internal integrator

Forward total, reverse total and difference total.

The output signal

Unidirectional analog output

Fully isolated, load ≤600D. When (20 ma); Upper limit: 0-21ma optional, lmA per gear; Lower limit: 0-21ma optional, 1mA per gear; Forward and reverse flow output programming.

Bidirectional analog output

The lower limit for. Or 4mA, same as one-way analog output.

Bidirectional pulse output

The two outputs correspond to the forward and reverse flow, respectively. The frequency is 0 ~ 800Hz, and the upper limit is 1 ~ 800Hz. Square wave or selected pulse width, upper limit of selected pulse width is 2.5s, 1ms per gear; Passive isolated transistor switch output, can absorb 250mA current, withstand 35V.

Dual output

(programmable) high/low flow rate, atc, fault state, forward, reverse flow rate, analog overrange, pulse overrange, pulse small signal removal, output polarity optional; Transistor switch output with isolation protection, can absorb 250mA current, withstand 35V.(not isolated from pulse output)

Digital communications


RS232, RS485, HART

Choice of lining

 

The lining material

The main performance

High dielectric temperature

Scope of application

- size

The separation type


Polytetrethylene (F4)

It is a kind of plastic with stable chemical properties, which can withstand boiling, sulfuric acid, ****** * and aqua regia, as well as strong alkali and various solvents. It is not resistant to corrosion of chemical, high temperature chemical, high velocity liquid, liquid oxygen and self-oxygen.

70 ℃

100℃ 150℃ (special order required)

1. Strong corrosive media such as concentrated acid and alkali. 2. Sanitary media.

Polyvinyl propylene (F46)

With F4, the wear resistance and negative pressure resistance were higher than F4.

Same as above


Polymerized vinyl (Fs)

Applicable temperature upper limit is lower than polytetrethylene, but the cost is also lower.

80 ℃


Butadiene rubber

1, some elastic, high tearing force, good wear resistance. 2, the general low concentration of acid, alkali, salt medium corrosion, not resistant to the corrosion of oxidizing media.

80℃ 120℃ (special order required)

Water, sewage, low abrasion mud slurry.

Polyurethane rubber

1, wear resistance is very strong.

2. Poor corrosion resistance.

80 ℃

Neutral wear of pulp, coal pulp, mud


 

Selection of inlet flange and ground flange (or ground ring)

 

The flange type

Comfortable with van

Ground flange (or ground ring)

Suitable for non-conductor pipes, such as plastic pipes, but sensors with ground electrodes are not required.

Import flange

Choose when the medium has a strong abrasion.

Electrode selection

Electrode materials

Corrosion and wear resistance

Stainless steel 0 crl8nil2m02ti

Used in industrial water, domestic water, sewage and other weakly corrosive media, suitable for petroleum, chemical, steel and other industrial sectors, municipal, environmental protection and other fields.

Hastelloy B

Has good corrosion resistance to all concentrations below the boiling point, but also resistant to sulfuric acid, acid, hydrogen acid, acid and other non-chemical acid, alkali, non-oxidizing salt solution corrosion.

Hastelloy C

Resistance to non-oxidizing acids, such as ******, mixed acid, or chromic acid and sulfuric acid mixed medium corrosion, also resistant to oxidizing salts such as: Fe, ", "Cu" or containing oxidizing agent corrosion, such as higher than normal temperature of the secondary acid solution, seawater corrosion

titanium

Ability to resist corrosion of seawater, various compounds and subacid, oxidizing acid (including fuming sulfuric acid), acid and alkali. It is not resistant to corrosion of pure reducing acid (such as sulfuric acid,), but when the acid contains oxidant (such as ******, f ++, c++), the corrosion is greatly reduced.

tantalum

It has excellent corrosion resistance similar to glass. In addition to hydrogen acid, fuming sulfuric acid, alkali, almost resistant to - - cutting chemical medium (including boiling point, ****** * and l sulfuric acid below 50℃) corrosion. Diao in alkali; Corrosion resistant.

Platinum/titanium alloy

Almost capable of cutting chemical media, but not suitable for aqua regia and ammonium salts.

Stainless steel coated with tungsten carbide

For non - corrosive, wear - resistant media.

Note: due to the wide variety of media, its corrosion and temperature, concentration, flow rate and other complex factors, the table is only for reference. Users should make their own choice according to the actual situation, and when necessary, should do the corrosion resistance test of the selected material, such as the hanging test.

Type selection of LD series electromagnetic flowmeter: measurement range: confirm the general industrial electromagnetic flowmeter with the measured medium flow rate of 2 ~ 4m/s is appropriate, in special cases, the low flow rate should not be less than 0.2m/s, the high should not be more than 8m/s. If the medium contains solid particles, the usual flow rate should be less than 3m/s to prevent excessive friction between the lining and the electrode. For viscous fluid, the flow rate can be selected to be greater than 2m/s. The larger flow rate is conducive to the effect of viscous material attached to the automatic electrode, which is conducive to improving the measurement accuracy. Under the condition of the range of Q have been identified, according to the velocity V can be decided to the size of the flow meter diameter D, the range of the values calculated by the next type: Q = PI D2V / 4 Q: flow (㎡ / h) D: pipe diameter V: velocity (m/h) electromagnetic flowmeter range of Q flow value should be greater than expected, the flow of the normal value in a full scale slightly greater than the flowmeter calibration 50 is advisable. ◆ LD series electromagnetic flowmeter reference flow range

 

Diameter in mm

Flow range m3/h

Diameter in mm

Flow range m3/h

Phi is 15

0.06 ~ 6.36

Phi 450

57.23 ~ 5722.65

Phi 20

0.11 ~ 11.3

Phi 500

70.65 ~ 7065.00

Phi is 25

0.18 ~ 17.66

Phi 600

101.74 ~ 10173.6

Phi 40

0.45 ~ 45.22

Phi 700

138.47 ~ 13847.4

Phi 50

0.71 ~ 70.65

Phi 800

180.86 ~ 18086.4

Phi 65

1.19 ~ 119.4

Phi 900

228.91 ~ 22890.6

Phi 80

1.81 ~ 180.86

Phi 1000

406.94 ~ 40694.4

Phi 100

2.83 ~ 282.60

Phi 1200

553.90 ~ 55389.6

Phi 150

6.36 ~ 635.85

Phi 1600

723.46 ~ 72345.6

Phi 200

11.3 ~ 1130.4

Phi 1800

915.62 ~ 91562.4

Phi 250

17.66 ~ 176.25.

Phi 2000

1130.4 ~ 113040.00

Phi 300

25.43 ~ 2543.40

Phi 2200

1367.78 ~ 136778.4

Phi 350

34.62 ~ 3461.85

Phi 2400

1627.78 ~ 162777.6

Phi 400

45.22 ~ 4521.6

Phi 2600

1910.38 ~ 191037.6

LDE series intelligent electromagnetic flowmeter spectrum selection

 

model

CAL


 LD

15~2600



Code name

Type of installation


Y

one-piece

F

Split type


Code name

Converter model

ZA

circular

ZB

square


Code name

The output signal

4 I.

4 ~ 20 ma

f

The frequency of 1 KHZ

The Rs

Serial communication (485)

C

Control the output


Code name

Explosion-proof requirements

 N

No explosion-proof

The EX

Explosion proof (for split type only)


Code name

Medium temperature

T1

65 ℃ or less

T2

120 ℃ or less

T3

≤180℃(for split-type only)


Code name

Lining material

NE

Butadiene rubber (≤65℃)

PTFE

Polytetrethylene (≤189℃)

PVC

Polyethylene (≤70℃)


Code name

The electrode material

316 l

Stainless steel

HC

Hastelloy C

HB

Hastelloy B

Ti

titanium

Ta

tantalum