Flame retardant computer cable
- cpfl:
This product is suitable for electrical computer and automation connection cables with rated voltage…
Description
I. product introduction |
This product is suitable for electrical computer and automation connection cables with rated voltage of 1000V and below. The insulation of cable ground core is k-type B low density polyethylene with oxidation resistance. The insulation resistance of polyethylene is high, the voltage resistance is good, the dielectric coefficient is small and the influence of dielectric loss temperature and variable frequency is small, not only can meet the requirement of transmission performance, but also can ensure the service life of the cable. In order to reduce mutual crosstalk and external interference between loops, the cable adopts shielding structure. The requirement of cable shielding is to adopt the following methods according to different occasions: wringing combination shielding, wringing combination forming total shielding of cable, total shielding after wringing combination shielding, etc. Shielding materials are round copper wire, copper tape, aluminum tape/plastic composite tape three kinds. The shielding pair and the shielding pair have good insulation performance. If the potential difference between the shielding pair and the shielding pair occurs during the use of the cable, the transmission quality of the signal will not be affected. |
Type, name and range of cable |
Type no. | The name says | Using range |
ZR - DJYVP | Flame retardant polythene insulated pair stranded copper wire braid total shielding flame retardant polyvinyl chloride sheathed computer cable | Fixed laying indoors, in cable ditches or in pipes |
ZR - DJYVP2 | Flame retardant polythene insulated pair of stranded copper tape total shielding flame retardant PVC sheathed computer cable | |
ZR - DJYVP3 | Flame retardant polythene insulated pair of stranded aluminum-plastic composite tape total shielding flame retardant PVC sheathed computer cable | |
ZR - DJYPV | Flame retardant polythene insulated pair stranded copper wire braided separately shielded flame retardant polyvinyl chloride sheathed computer cable | |
ZR - DJYP2V | Flame retardant polythene insulated pair of copper tape separately shielded flame retardant PVC sheathed computer cable | |
ZR - DJYP3V | Flame retardant polythene insulated pair of stranded aluminum-plastic composite tape separately shielded flame retardant PVC sheathed computer cable | |
ZR - DJYPVP | Flame retardant polythene insulated pair of copper wire and total shielding flame retardant PVC sheathed computer cables | |
ZR - DJYP2VP2 | Flame retardant polythene insulated pair of twisted copper tape separate shield and total shield flame retardant PVC sheathed computer cable | |
ZR - DJYP3VP3 | Flame retardant polythene insulated pair of stranded aluminum-plastic composite tape and total shielding flame retardant PVC sheathed computer cable | |
ZR - DJYVPR | Flame retardant polythene insulated pair of copper wire braided with total shielding flame retardant polyvinyl chloride sheathed computer soft cable | Suitable for occasions requiring frequent movement or softness |
ZR - DJYVP2R | Flame retardant polythene insulated pair copper tape total shielding flame retardant PVC sheathed computer cable | |
ZR - DJYVP3R | Flame retardant polythene insulated pair of stranded aluminum-plastic composite tape with total shielding flame retardant PVC sheathed computer soft cable | |
ZR - DJYPVR | Flame retardant polythene insulated pair stranded copper wire braided separately shielded flame retardant PVC sheathed computer soft cable | |
ZR - DJYP2VR | Flame retardant polythene insulated pair of copper tape separately shielded flame retardant PVC sheathed computer cable | |
ZR - DJYP3VR | Flame retardant polythene insulated pair of stranded aluminum-plastic composite tape separately shielded flame retardant PVC sheathed computer soft cable | |
ZR - DJYPVPR | Flame retardant polythene insulated pair copper wire braided subshield and total shield flame retardant PVC sheathed computer soft cable | |
ZR - DJYP2VP2R | Flame retardant polythene insulated pair of copper tape separate shield and total shield flame retardant PVC sheathed computer cable | |
ZR - DJYP3VP3R | Flame retardant polythene insulated flexible cable for computer with separate shield and total shield for flame retardant polyvinyl chloride sheathed composite tape | |
ZR - DJYVP22 | Flame retardant polythene insulated pair stranded copper wire braided main screen sheathed flame retardant PVC sheathed computer cable | Directly buried installation |
ZR - DJYVP2-22 | Flame retardant polythene insulated pair of copper tape main screen shield steel tape armored flame retardant PVC sheathed computer cable | |
ZR - DJYVP3-22 | Flame retardant polythene insulated pair of stranded aluminum-plastic composite tape main screen shield steel tape armored flame retardant polyvinyl chloride sheathed computer cable | |
ZR - DJYPVP22 | Flame retardant polythene insulated pair braided copper wire braided separate shield and total screen shield steel tape armored flame retardant polyvinyl chloride sheathed computer soft cable | |
ZR - DJYP2VP2-22 | Flame retardant polythene insulated pair copper tape split shield and total screen shield steel tape armored flame retardant polyvinyl chloride sheathed computer cable | |
ZR - DJYP3VP3-22 | Polythene insulated pair of sheathed aluminum-plastic composite tape and main screen shield steel tape armored flame retardant PVC sheathed computer soft cable | |
ZR - DJYP3VP3-32 | Crosslinked polyethylene insulated pair of stranded aluminum-plastic composite tape separate shield and total shield phosphating fine steel wire armored flame retardant PVC sheathed computer soft cable | Directly buried installation |
DZR - JYP3VP3-92 | Crosslinked polyethylene insulated pair of stranded aluminum-plastic composite tape separate shield and total shield fine wire braid flame retardant PVC sheathed computer soft cable | Fixed laying indoors, in cable ditches or in pipes |
ZR - NHDJYP3VP3-32 | The copper conductor is covered with refractory mica tape, and the crosslinked polyethylene is insulated against the stranded aluminum-plastic composite tape | Directly buried installation |
ZR - NHDJYP3VP3-92 | The copper conductor is covered with refractory mica tape, and the crosslinked polyethylene is insulated with a separate shield for the stranded aluminum-plastic composite tape and a total shield for the fine wire braid flame retardant PVC sheathed computer soft cable | Fixed laying indoors, in cable ditches or in pipes |
Browse: