Compensation wire and compensation cable for thermocouple
- cpfl:
Description
Product description: |
I. product features and USES Generally, PVC insulated and sheathed compensation wires or cables have excellent moisture-proof, wear-resistant and flame retardant characteristics; High temperature resistant fluoroplastic insulation and sheath compensation wire or cable using continuous extrusion process, more high temperature resistance, cold resistance, acid and alkali oil and water resistance, non-ignition, anti-aging and other advantages, product quality is higher than GB/ t4989-94 (equivalent to the use of iec584-3) provisions. Anquan explosion-proof temperature measuring system is made of compensation wire or cable with low capacitance and low inductance material structure, with explosion-proof anquan performance, suitable for explosion-proof thermocouple cooling and explosion-proof temperature measuring meter connection under the environment of explosion risk, forming the local safety thermocouple temperature measuring system. Ii. Product implementation standards GB/ t4989-94 (equivalent to iec584-3) Three: use features 1. Conductor *** high operating temperature: heat resistant grade: polyperfluorinated ethylene propylene (F46)200℃ Soluble polytetrafluoroethylene 260℃ Silicone rubber was 180 ℃ Normal grade: PVC 70℃ and 105℃, crosslinked polyethylene 90℃ Low smoke halogen-free flame retardant polyolefin 70℃, crosslinked 90℃ and 125℃ 2. Low ambient temperature: PVC sheath: fixed laying -40℃, non-fixed laying -15℃ Fluoroplastic insulation and sheath: fixed laying -60℃, non-fixed laying -20℃ 3. Cable allowed bending radius: unarmored cable *** small to 6 times outside diameter Copper tape shielded or steel tape armored cables are 12 times smaller than the outside diameter of the cable The fluoroplastic insulation and sheath are 10 times smaller than the outside diameter of the cable Iv. Basic model and name 1: compensation wire for thermocouple |
KX - GA - VV | PVC insulated PVC sheathed precision grade K scale thermocouple compensation conductor |
KX - GA - VVR | PVC insulated PVC sheathed precision grade K scale thermocouple compensated flexible conductor |
KX - GA - VVP | PVC insulated PVC sheathed copper wire braided shield precision grade K scale thermocouple compensation conductor |
KX - GA - VVRP | PVC insulated PVC sheathed copper wire braided shield precision grade K scale number thermocouple compensation soft conductor |
KX - HA - FF | Fluoroplastic insulation and sheath precision grade K scale thermocouple compensation wire |
KX - HA - FFR | Fluoroplastic insulation and sheathing precision grade K scale thermocouple compensation soft conductor |
KX - HA - FFP | Fluoroplastic insulated and sheathed copper wire braided shielding precision grade K scale thermocouple compensation wire |
KX - HA - FFRP | Fluoroplastic insulated and sheathed copper wire braided shield precision grade K scale number thermocouple compensated soft conductor |
KX - HA - FG | Fluoroplastic insulated silicone rubber sheathed precision grade K scale thermocouple compensation wire |
KX - HA - FGR | Fluoroplastic insulated silicone rubber sheathed precision grade K scale thermocouple compensation soft wire |
KX - HA - FGP | Fluoroplastic insulated silicone rubber sheathed copper wire braided shield precision grade K scale thermocouple compensation wire |
KX - HA - FGRP | Fluoroplastic insulated silicone rubber sheathed copper wire braided shield precision grade K scale number thermocouple compensation soft wire |
KX - HA - FV | Fluoroplastic insulated polyvinyl chloride sheathed precision grade K scale thermocouple compensation conductor |
KX - HA - FVR | Fluoroplastic insulated polyvinyl chloride sheathed precision grade K scale thermocouple compensated flexible conductor |
KX - HA - FVP | Fluoroplastic insulated polyvinyl chloride sheathed copper wire braided shield precision grade K scale thermocouple compensation wire |
KX - HA - FVRP | Fluoroplastic insulated polyvinyl chloride sheathed copper wire braided shield precision grade K scale number thermocouple compensation soft conductor |
KX - GA - YJV | Crosslinked polyethylene insulated polyvinyl chloride sheathed precision grade K scale thermocouple compensation conductor |
KX - GA - YJVR | Crosslinked polyethylene insulated polyvinyl chloride sheathed precision grade K scale thermocouple compensated flexible conductor |
KX - GA - YJVP | Crosslinked polyethylene insulated PVC sheathed copper wire braided shield precision grade K scale thermocouple compensation conductor |
KX - GA - YJVRP | Low smoke halogen free insulation and sheath copper wire braid shield precision grade K scale number thermocouple compensation soft conductor |
KX - GA - YDYD | Low smoke halogen free insulation and sheath precision grade K scale thermocouple compensation conductor |
KX - GA - YDYD R | Low smoke halogen free insulation and sheath precision grade K rating thermocouple compensation soft conductor |
KX - GA - YDYD P | Low smoke halogen free insulated and sheathed copper wire braided shielding precision grade K scale thermocouple compensation wire |
KX - GA - YDYD RP | Low smoke halogen free insulation and sheath copper wire braid shield precision grade K scale number thermocouple compensation soft conductor |
Note: the above models *** list KX, others such as SC, KC, EX, BC, TX, JX only need to change the model *****, ZR and ZR192 are imported PFA materials. The shield can be shielded by tinned copper wire. |
Compensating conductor for local safety thermocouple
IA - KX - GA - YVP | Polyethylene insulated polyvinyl chloride sheathed copper wire braided shield precision grade K index no |
IA - KX - GA - YVRP | Polyethylene insulated polyvinyl chloride sheathed copper wire braided shield precision grade K index no |
IA - KX - HA - FFP | Fluoroplastic insulated and sheathed copper wire braided shielding precision grade K index no |
IA - KX - HA - FFRP | Fluoroplastic insulated and sheathed copper wire braided shield precision grade K scale no |
IA - KX - HA - FGP | Fluoroplastic insulated silicone rubber sheathed copper wire braided shield precision grade K index no |
IA - KX - HA - FGRP | Fluoroplastic insulated silicone rubber sheathed copper wire braided shield precision grade K index no |
Note: the above models *** list KX, others such as SC, KC, EX, NC, TX, JX only need to change the model *****, Add ZR before the model, ZR192 is imported PFA material, The shield can be shielded by tinned copper wire. |
3: compensation cable
KX - GA - VVP | PVC insulated and sheathed copper wire braided total shielding precision grade K index number thermocouple compensation cable |
KX - GA - VVRP | PVC insulated and sheathed copper wire braided total shielding precision grade K index number thermocouple compensation flexible cable |
KX - GA - VPVP | Compensation cable for PVC insulated and sheathed copper wire braided split screen combined shield precision grade K index thermocouple |
KX - GA - VPVRP | Polyvinyl chloride insulated and sheathed copper wire braided split screen combined shield precision grade K index number thermocouple compensation flexible cable |
KX - GA - YJVP | Crosslinked polyethylene insulated polyvinyl chloride sheathed copper wire braid total shielding precision grade K division number thermocouple compensation cable |
KX - GA - YJVRP | Crosslinked polyethylene insulated polyvinyl chloride sheathed copper wire braid total shielding precision grade K division number thermocouple compensation flexible cable |
KX - GA - YJPVP | Crosslinked polyethylene insulated polyvinyl chloride sheathed copper wire braided split screen combined shield precision grade K division number thermocouple compensation cable |
KX - GAYJPVRP | Crosslinked polyethylene insulated polyvinyl chloride sheathed copper wire braided split screen combined shield precision grade K index number thermocouple compensation flexible cable |
KX - HA - FFP | FPC insulated and sheathed copper wire braided total shielding precision grade K index number thermocouple compensation cable |
KX - HA - FFRP | FPC insulated and sheathed copper wire braided total shielding precision grade K index number thermocouple compensation flexible cable |
KX - HA - FPFP | Compensation cables for fluoroplastic insulated and sheathed copper wire braided split screen combined shield precision grade K index thermocouple |
KX - HA - FPFRP | Fluoroplastic insulated and sheathed copper wire braided split screen combined shield precision grade K index number thermocouple compensation flexible cable |
KX - HA - FVP | Fluorofenes insulated polyvinyl chloride sheathed copper wire braid total shielding precision grade K index number thermocouple compensation cable |
KX - HA - FVRP | Fluorofenes insulated polyvinyl chloride sheathed copper wire braid total shielding precision grade K index number thermocouple compensation flexible cable |
KX - HA - FPVP | Fluoroplastic insulated polyvinyl chloride sheathed copper wire braided split screen combined shield precision grade K index number thermocouple compensation cable |
KX - HA - FPVRP | Fluoroplastic insulated polyvinyl chloride sheathed copper wire braided split screen combined shield precision grade K index number thermocouple compensation flexible cable |
KX - HA - FGP | FPC insulated silicone rubber sheathed copper wire braid total shielding precision grade K index number thermocouple compensation cable |
KX - HA - FGRP | FPC insulated silicone rubber sheathed copper wire braid total shielding precision grade K index number thermocouple compensation flexible cable |
KX - HA - FPGP | Fluoroplastic insulated silicone rubber sheathed copper wire braided split screen summing shield precision grade K index number thermocouple compensation cable |
KX - HA - FPGRP | Fluoroplastic insulated silicone rubber sheathed copper wire braided split screen combined shield precision grade K index number thermocouple compensation flexible cable |
Note: 1 above basic models *** list the shielding methods of copper wire or tinned wire. Other shielding types only need to change the shielding code, such as P2 and P3 2. Add ZR before model for flame retardant type, 22 after model for armored cable, ZR192 for imported PFA material, temperature resistance 260℃ |
4: safety compensation cable
IA - KX - GA - FPVP | Fluoroplastic insulated polyvinyl chloride sheathed copper wire braided split screen combined shield precision grade K index no |
IA - KX - GA - FPVRP | Fluoroplastic insulated polyvinyl chloride sheathed copper wire braided split screen combined shield precision grade K index no |
IA - KX - HA - FPFP | Compensation cable for fluoroplastic insulated and sheathed copper wire braided split screen combined shield precision grade K index no |
IA - KX - HA - FPFRP | Fluoroplastic insulated and sheathed copper wire braided split screen combined shield precision grade K index no |
IA - KX - HA - FPGP | Fluoroplastic insulated silicone rubber sheathed copper wire braided split screen combined shield precision grade K index no |
IA - KX - HA - FPGRP | Fluoroplastic insulated silicone rubber sheathed copper wire braided split screen combined shield precision grade K index no |
Note: 1 above basic models *** list the shielding methods of copper wire or tinned wire. Other shielding types only need to change the shielding code, such as P2 and P3 2. Add ZR before model for flame retardant type, 22 after model for armored cable, ZR192 for imported PFA material, temperature resistance 260℃ |
Five: code name and meaning
Table 2.
project | Code name | instructions |
Flame retardant properties | ZR | Grade A, B, C flame retardant |
A series of codes | / IA | None (ben-safe type) |
Insulation materials | Y | polyethylene |
YJ | Crosslinked polyethylene | |
YD | Low smoke halogen-free flame retardant polyolefin | |
F | Polyperfluoroethylene propylene (F46) or soluble polytetrafluoroethylene (PFA) | |
Sheath material | YD | Low smoke halogen-free flame retardant polyolefin |
V | Polyvinyl chloride (PVC) | |
F | Polyperfluoroethylene propylene (F46) or soluble polytetrafluoroethylene (PFA) | |
G | Silicone rubber | |
Shielding materials | P | Copper wire braid shield |
The P2 | Copper tape wrap shield | |
P3 | Aluminum-plastic composite tape wrapping shield | |
Conductor structure | a. | Single strand conductors |
B | 7 strands stranded conductor | |
R | Stranded conductor |