Compensation wire and compensation cable for thermocouple

cpfl:
Generally, PVC insulated and sheathed compensation wires or cables have excellent moisture-proof, we…
Description

Product description:

 

I. product features and USES

Generally, PVC insulated and sheathed compensation wires or cables have excellent moisture-proof, wear-resistant and flame retardant characteristics; High temperature resistant fluoroplastic insulation and sheath compensation wire or cable using continuous extrusion process, more high temperature resistance, cold resistance, acid and alkali oil and water resistance, non-ignition, anti-aging and other advantages, product quality is higher than GB/ t4989-94 (equivalent to the use of iec584-3) provisions.

Anquan explosion-proof temperature measuring system is made of compensation wire or cable with low capacitance and low inductance material structure, with explosion-proof anquan performance, suitable for explosion-proof thermocouple cooling and explosion-proof temperature measuring meter connection under the environment of explosion risk, forming the local safety thermocouple temperature measuring system.

Ii. Product implementation standards

GB/ t4989-94 (equivalent to iec584-3)

Three: use features

1. Conductor *** high operating temperature: heat resistant grade: polyperfluorinated ethylene propylene (F46)200℃

Soluble polytetrafluoroethylene 260℃

Silicone rubber was 180 ℃

Normal grade: PVC 70℃ and 105℃, crosslinked polyethylene 90℃

Low smoke halogen-free flame retardant polyolefin 70℃, crosslinked 90℃ and 125℃

2. Low ambient temperature: PVC sheath: fixed laying -40℃, non-fixed laying -15℃

Fluoroplastic insulation and sheath: fixed laying -60℃, non-fixed laying -20℃

3. Cable allowed bending radius: unarmored cable *** small to 6 times outside diameter

Copper tape shielded or steel tape armored cables are 12 times smaller than the outside diameter of the cable

The fluoroplastic insulation and sheath are 10 times smaller than the outside diameter of the cable

Iv. Basic model and name

1: compensation wire for thermocouple

KX - GA - VV

PVC insulated PVC sheathed precision grade K scale thermocouple compensation conductor

KX - GA - VVR

PVC insulated PVC sheathed precision grade K scale thermocouple compensated flexible conductor

KX - GA - VVP

PVC insulated PVC sheathed copper wire braided shield precision grade K scale thermocouple compensation conductor

KX - GA - VVRP

PVC insulated PVC sheathed copper wire braided shield precision grade K scale number thermocouple compensation soft conductor

KX - HA - FF

Fluoroplastic insulation and sheath precision grade K scale thermocouple compensation wire

KX - HA - FFR

Fluoroplastic insulation and sheathing precision grade K scale thermocouple compensation soft conductor

KX - HA - FFP

Fluoroplastic insulated and sheathed copper wire braided shielding precision grade K scale thermocouple compensation wire

KX - HA - FFRP

Fluoroplastic insulated and sheathed copper wire braided shield precision grade K scale number thermocouple compensated soft conductor

KX - HA - FG

Fluoroplastic insulated silicone rubber sheathed precision grade K scale thermocouple compensation wire

KX - HA - FGR

Fluoroplastic insulated silicone rubber sheathed precision grade K scale thermocouple compensation soft wire

KX - HA - FGP

Fluoroplastic insulated silicone rubber sheathed copper wire braided shield precision grade K scale thermocouple compensation wire

KX - HA - FGRP

Fluoroplastic insulated silicone rubber sheathed copper wire braided shield precision grade K scale number thermocouple compensation soft wire

KX - HA - FV

Fluoroplastic insulated polyvinyl chloride sheathed precision grade K scale thermocouple compensation conductor

KX - HA - FVR

Fluoroplastic insulated polyvinyl chloride sheathed precision grade K scale thermocouple compensated flexible conductor

KX - HA - FVP

Fluoroplastic insulated polyvinyl chloride sheathed copper wire braided shield precision grade K scale thermocouple compensation wire

KX - HA - FVRP

Fluoroplastic insulated polyvinyl chloride sheathed copper wire braided shield precision grade K scale number thermocouple compensation soft conductor

KX - GA - YJV

Crosslinked polyethylene insulated polyvinyl chloride sheathed precision grade K scale thermocouple compensation conductor

KX - GA - YJVR

Crosslinked polyethylene insulated polyvinyl chloride sheathed precision grade K scale thermocouple compensated flexible conductor

KX - GA - YJVP

Crosslinked polyethylene insulated PVC sheathed copper wire braided shield precision grade K scale thermocouple compensation conductor

KX - GA - YJVRP

Low smoke halogen free insulation and sheath copper wire braid shield precision grade K scale number thermocouple compensation soft conductor

KX - GA - YDYD

Low smoke halogen free insulation and sheath precision grade K scale thermocouple compensation conductor

KX - GA - YDYD R

Low smoke halogen free insulation and sheath precision grade K rating thermocouple compensation soft conductor

KX - GA - YDYD P

Low smoke halogen free insulated and sheathed copper wire braided shielding precision grade K scale thermocouple compensation wire

KX - GA - YDYD RP

Low smoke halogen free insulation and sheath copper wire braid shield precision grade K scale number thermocouple compensation soft conductor

Note: the above models *** list KX, others such as SC, KC, EX, BC, TX, JX only need to change the model *****,

ZR and ZR192 are imported PFA materials.

The shield can be shielded by tinned copper wire.

Compensating conductor for local safety thermocouple

IA - KX - GA - YVP

Polyethylene insulated polyvinyl chloride sheathed copper wire braided shield precision grade K index no

IA - KX - GA - YVRP

Polyethylene insulated polyvinyl chloride sheathed copper wire braided shield precision grade K index no

IA - KX - HA - FFP

Fluoroplastic insulated and sheathed copper wire braided shielding precision grade K index no

IA - KX - HA - FFRP

Fluoroplastic insulated and sheathed copper wire braided shield precision grade K scale no

IA - KX - HA - FGP

Fluoroplastic insulated silicone rubber sheathed copper wire braided shield precision grade K index no

IA - KX - HA - FGRP

Fluoroplastic insulated silicone rubber sheathed copper wire braided shield precision grade K index no

Note: the above models *** list KX, others such as SC, KC, EX, NC, TX, JX only need to change the model *****,

Add ZR before the model, ZR192 is imported PFA material,

The shield can be shielded by tinned copper wire.

3: compensation cable


KX - GA - VVP

PVC insulated and sheathed copper wire braided total shielding precision grade K index number thermocouple compensation cable

KX - GA - VVRP

PVC insulated and sheathed copper wire braided total shielding precision grade K index number thermocouple compensation flexible cable

KX - GA - VPVP

Compensation cable for PVC insulated and sheathed copper wire braided split screen combined shield precision grade K index thermocouple

KX - GA - VPVRP

Polyvinyl chloride insulated and sheathed copper wire braided split screen combined shield precision grade K index number thermocouple compensation flexible cable

KX - GA - YJVP

Crosslinked polyethylene insulated polyvinyl chloride sheathed copper wire braid total shielding precision grade K division number thermocouple compensation cable

KX - GA - YJVRP

Crosslinked polyethylene insulated polyvinyl chloride sheathed copper wire braid total shielding precision grade K division number thermocouple compensation flexible cable

KX - GA - YJPVP

Crosslinked polyethylene insulated polyvinyl chloride sheathed copper wire braided split screen combined shield precision grade K division number thermocouple compensation cable

KX - GAYJPVRP

Crosslinked polyethylene insulated polyvinyl chloride sheathed copper wire braided split screen combined shield precision grade K index number thermocouple compensation flexible cable

KX - HA - FFP

FPC insulated and sheathed copper wire braided total shielding precision grade K index number thermocouple compensation cable

KX - HA - FFRP

FPC insulated and sheathed copper wire braided total shielding precision grade K index number thermocouple compensation flexible cable

KX - HA - FPFP

Compensation cables for fluoroplastic insulated and sheathed copper wire braided split screen combined shield precision grade K index thermocouple

KX - HA - FPFRP

Fluoroplastic insulated and sheathed copper wire braided split screen combined shield precision grade K index number thermocouple compensation flexible cable

KX - HA - FVP

Fluorofenes insulated polyvinyl chloride sheathed copper wire braid total shielding precision grade K index number thermocouple compensation cable

KX - HA - FVRP

Fluorofenes insulated polyvinyl chloride sheathed copper wire braid total shielding precision grade K index number thermocouple compensation flexible cable

KX - HA - FPVP

Fluoroplastic insulated polyvinyl chloride sheathed copper wire braided split screen combined shield precision grade K index number thermocouple compensation cable

KX - HA - FPVRP

Fluoroplastic insulated polyvinyl chloride sheathed copper wire braided split screen combined shield precision grade K index number thermocouple compensation flexible cable

KX - HA - FGP

FPC insulated silicone rubber sheathed copper wire braid total shielding precision grade K index number thermocouple compensation cable

KX - HA - FGRP

FPC insulated silicone rubber sheathed copper wire braid total shielding precision grade K index number thermocouple compensation flexible cable

KX - HA - FPGP

Fluoroplastic insulated silicone rubber sheathed copper wire braided split screen summing shield precision grade K index number thermocouple compensation cable

KX - HA - FPGRP

Fluoroplastic insulated silicone rubber sheathed copper wire braided split screen combined shield precision grade K index number thermocouple compensation flexible cable

Note: 1 above basic models *** list the shielding methods of copper wire or tinned wire. Other shielding types only need to change the shielding code, such as P2 and P3

2. Add ZR before model for flame retardant type, 22 after model for armored cable, ZR192 for imported PFA material, temperature resistance 260℃


4: safety compensation cable


IA - KX - GA - FPVP

Fluoroplastic insulated polyvinyl chloride sheathed copper wire braided split screen combined shield precision grade K index no

IA - KX - GA - FPVRP

Fluoroplastic insulated polyvinyl chloride sheathed copper wire braided split screen combined shield precision grade K index no

IA - KX - HA - FPFP

Compensation cable for fluoroplastic insulated and sheathed copper wire braided split screen combined shield precision grade K index no

IA - KX - HA - FPFRP

Fluoroplastic insulated and sheathed copper wire braided split screen combined shield precision grade K index no

IA - KX - HA - FPGP

Fluoroplastic insulated silicone rubber sheathed copper wire braided split screen combined shield precision grade K index no

IA - KX - HA - FPGRP

Fluoroplastic insulated silicone rubber sheathed copper wire braided split screen combined shield precision grade K index no

Note: 1 above basic models *** list the shielding methods of copper wire or tinned wire. Other shielding types only need to change the shielding code, such as P2 and P3

2. Add ZR before model for flame retardant type, 22 after model for armored cable, ZR192 for imported PFA material, temperature resistance 260℃


Five: code name and meaning

Table 2.


project

Code name

instructions

Flame retardant properties

ZR

Grade A, B, C flame retardant

A series of codes

/ IA

None (ben-safe type)

Insulation materials

Y

polyethylene

YJ

Crosslinked polyethylene

YD

Low smoke halogen-free flame retardant polyolefin

F

Polyperfluoroethylene propylene (F46) or soluble polytetrafluoroethylene (PFA)

Sheath material

YD

Low smoke halogen-free flame retardant polyolefin

V

Polyvinyl chloride (PVC)

F

Polyperfluoroethylene propylene (F46) or soluble polytetrafluoroethylene (PFA)

G

Silicone rubber

Shielding materials

P

Copper wire braid shield

The P2

Copper tape wrap shield

P3

Aluminum-plastic composite tape wrapping shield

Conductor structure

a.

Single strand conductors

B

7 strands stranded conductor

R

Stranded conductor